Keeping solar and storage plants reliable — and the grid stable.
Solstice Energy helps owners, operators and EPCs get the most out of existing PV and battery plants: commissioning support, performance reviews, protection and grounding checks, O&M procedures and field-team training.
Plants that are built are not always plants that perform.
Grid operators have documented solar plants reducing output during grid disturbances because of their own inverter and protection settings, not the fault itself. Poor commissioning, untested grounding and unmonitored losses cost energy, revenue and grid stability.
We focus on the details that decide whether a plant runs safely and reliably for 25+ years.
- Protection and inverter settings that ride through grid events
- Commissioning tests that are documented and repeatable
- Grounding systems verified by measurement, not assumption
- Performance losses found early from monitoring data
- Field teams trained on clear, standard procedures
Support across the plant lifecycle
From feasibility to post-installation operation. Each service has a simple way to start.
Performance Analysis
Performance ratio (IEC 61724), expected vs. actual yield, and a ranked list of likely losses from your monitoring data.
Post-Installation & O&M
Preventive and corrective maintenance procedures, thermography, IV-curve testing and ground grid resistance measurement.
Compliance & Grid Readiness
Review of interconnection and ride-through readiness against IEEE 1547, UL 1741 SB and current reliability guidance.
Feasibility & Financial Reports
Technical and economic pre-feasibility for PV and PV + storage: yield, savings, payback and key project risks.
Technical Training
Practical training for O&M and commissioning teams: procedures, safety practices, troubleshooting and video guides.
Monitoring, SCADA & Data
Data templates and dashboards for availability, losses and alarms, plus SCADA integration and end-to-end test checklists.
Free Performance Check
Send us your plant data and we return a short report with your performance ratio, a comparison with expected generation, and the three most likely sources of loss.
Commercial, industrial and utility-scale PV in the United States. Your data is used only to prepare your report.
- Fill in the contact form and choose “Free Performance Check”.
- Send a CSV export from your monitoring system (hourly or daily energy), plus system size, location and inverter model.
- Receive your report by email.
Technical papers, guides and videos
Free material for engineers, technicians and plant operators.
Commissioning Sequence for Solar PV Plants
The order of commissioning from mechanical completion to commercial operation, with hold points and the U.S. documents behind each step.
Read more →Medium-Voltage Cable Acceptance Testing
Shield continuity, insulation resistance and VLF withstand testing of new medium-voltage cable systems before first energization.
Read more →Grounding Grid and Ground-Fault Protection Compatibility
A method to check whether a grounding grid is safe for the fault-clearing times the protection actually delivers, with a worked example.
Read more →Weather-Corrected Performance Ratio of a Utility-Scale PV Plant
How to calculate a weather-corrected performance ratio from SCADA data and compare it with the simulation and the guarantee.
Read more →Grounding Grid Resistance Measurement
How to measure the ground resistance of PV, BESS and substation grids by the fall-of-potential method, following IEEE Std 81.
Read more →Solstice Energy on YouTube
Short, practical explainers on commissioning, testing and O&M.
Watch videosField experience, applied to U.S. plants
Solstice Energy is led by Vinicius Leoni, an electrical engineer licensed in Brazil with more than nine years of hands-on work on photovoltaic plants: design, grid connection, protection and selectivity studies, arc flash studies and commissioning.
He has commissioned more than 40 PV plants, including writing their commissioning plans, and is a member of IEEE Power & Energy Society. Solstice brings that field experience to the U.S. market with a focus on reliability, safety and measurable performance.
Figures refer to projects carried out in Brazil.
Tell us about your plant
We usually reply within two business days.